- 23 -
5.5 Common parameter setting mode SET 4 (2)
SET04
Name
Setting content
Initial value
31
MV2
Secondary control operating amount
0.0 to 100.0 (%)
0.0
32
PC1
Secondary control proportional band setting for PID
No. 1 (low temperature)
0.10 to 10.00 (times)
1.00
33
PC2
Secondary control proportional band setting for PID
No. 2 (intermediate temperature)
0.10 to 10.00 (times)
1.00
34
PC3
Secondary control proportional band setting for PID
No. 3 (high temperature)
0.10 to 10.00 (times)
1.00
35
T2
Secondary control proportional cycle
0.1 to 120.0 (seconds)
1.0
36
PS2
Secondary control loop abnormality
PV variation setting
Thermocouple/RTD input 0.0 to 999.9 (C) or 0 to 999 (C)
0
Current/voltage input 0 to 9999 (digit)
37
LOP2
Secondary control loop abnormality time setting
0 to 3600 (seconds)
0
38
C2
Secondary control sensitivity setting
Thermocouple/RTD input 0.0 to 999.9 (C) 0 to 999 (C)
1
Current/voltage input 0 to 9999 (digit)
10
39
CP2
Secondary control off-point position
Thermocouple/RTD input -999.9 to 999.9 (C) -999 to 999
(C)
0
Current/voltage input -9999 to 9999 (digit)
40
PBB
Manual reset
0.0 to 100.0 (%) when CNT = 1
-100.0 to 100.0 (%) when CNT = 3 and 4
0.0
41
DB
Dead band
Thermocouple/RTD input -999.9 to 999.9 (C) -999 to 999
(C)
0
Current/voltage input -9999 to 9999 (digit)
42
O1F
Target connection output 1 selection
Connection content selection
0
MV1
0
1
MV2
2
Transmission output
43
TRN1
Transmission output function setting
Transmission content selection
03
*1
PV (measurement value) output
*2
SV (setting value) output
*3
MV 1 (Primary Control Amt.) output
*4
MV 2 (Secondary Control Amt.) output
Forward/reverse operation selection
0*
Forward operation
1*
Reverse operation
44
TRH1
Transmission scaling upper limit setting
TRL1~2999.9() or TRL1~2999()
1200
45
TRL1
Transmission scaling lower limit setting
-1999.9TRH1 () or -1999TRH1 ()
0
46
O2F
Target connection output 1 selection
Connection content selection
0
MV1
1
1
MV2
2
Transmission output
47
TRN2
Transmission output function setting
Transmission content selection
04
*1
PV (measurement value) output
*2
SV (setting value) output
*3
MV1 (Primary Control Amt.) output
*4
MV2 (Secondary Control Amt.) output
Forward/reverse operation selection
0*
Forward operation
1*
Reverse operation
48
TRH2
Transmission scaling upper limit setting
TRL2~2999.9() or TRL2~2999()
1200
49
TRL2
Transmission scaling lower limit setting
-1999.9TRH2 () or -1999TRH2 ()
0