TOHO ELECTRONICS INC.
Operation Manual, Communications
(TOHO protocol and MODBUS)
Model : TTM-000 Series
Designation : Digital Controller
Zobrazit stránku 0
1 2 3 4 5 6 ... 41 42

Shrnutí obsahu

Strany 1 - TOHO ELECTRONICS INC

1 TOHO ELECTRONICS INC. Operation Manual, Communications (TOHO protocol and MODBUS) Model : TTM-000 Ser

Strany 2 - Contents

10 3.4 Composition of a response message (transmitted from this product to a high-level computer) For codes ① to ⑩, see "3.5 Descriptio

Strany 3

11 3.5 Description of codes The codes from ① STX, ② address to ⑩ ERR type as indicated below are expressed in ASCII codes. For the ASCI

Strany 4

12 ⑥ ETX This code is needed for the receiver to detect the end of a message. It is affixed to the end of a character string to be sent (except f

Strany 5 - 2.1 Overview

13 3.6 Communications precautions 3.6.1 Communications timing Set a sufficient response delay to make sure that this product is switched over fr

Strany 6

14 3.6.8 Storing data other than a store request message Store all parameters in the EEPROM in either of the two cases described below, even if no

Strany 7

15 4. Examples of TOHO communications 4.1 Examples of communications to be read Example: Request message: This requests this product set at addres

Strany 8 - 3.2 Message types

16 4.2 Examples of communications to be written Example: Request message: This requests this product set at address 03 to set "the E1F settin

Strany 9

17 5. Settings regarding MODBUS communications 5.1 Overview Before communications is performed, initial settings must be made on this product. E

Strany 10 - Negative

18 5.2 Setting a data length 5.3 Setting a stop bit length 5.4 Setting a parity 5.5 Setting a BCC check The BCC check is disabled. Initial v

Strany 11 - 3.5 Description of codes

19 5.8 Setting a response delay Set a time from the time when the high-level computer finished sending a "request message" until the time

Strany 12

2 Thank you very much for purchasing a TTM-000 Series (with communications). Please read this operation manual carefully and use this product correctl

Strany 13

20 6. MODBUS communications control 6.1 Communications procedure This product returns a "response message" in response to a "requ

Strany 14

21 6.3 Composition of an RTU request message (transmitted from a high-level computer to this product) For codes a) through i), see "6.5 Desc

Strany 15

22 6.4 Composition of an RTU response message (transmitted from this product to a high-level computer) For codes a) through h), see "6.5 D

Strany 16

23 6.5 Description of RTU codes The codes from a) slave address to b) function code to h) error code shown below are expressed in 8-bit binary nu

Strany 17 - 5.1 Overview

24 g) Data portion This specifies data to be written in the register. The data is fixed at 4 bytes. This product will write data without the

Strany 18

25 6.6 Precautions on RTU communications 6.6.1 Communications timing Set a sufficient response delay to make sure that this product is switched

Strany 19

26 6.6.8 Storing data other than a store request message This product will store all parameters in the EEPROM in either of the two cases described

Strany 20 - 6.2 Message types

27 6.8 Composition of an ASCII request message (transmitted from a high-level computer to this product) For the codes a) through g), see "

Strany 21

28 6.8.3 Composition of a store request message a) Start code “:” b) Slave address “0” , “3” c) Function code “1” , “0” d) Register address Hig

Strany 22

29 6.9 Composition of ASCII response messages (transmitted from this product to a high-level computer) For the codes a) through g), see "6

Strany 23

3 6. MODBUS communications control ... 20 6.1 Communications procedu

Strany 24

30 6.10 Description of ASCII codes The codes from a) start code to b) slave address to j) error type described below are expressed in ASCII codes

Strany 25

31 i) Data portion This specifies data to be written in the register. The data is fixed at 4 bytes. This product will write data without the deci

Strany 26

32 6.11 Precautions on ASCII communications 6.11.1 Communications timing Set a sufficient response delay to make sure that this product is switc

Strany 27

33 6.11.8 Storing data other than a store request message This product will store all parameters in the EEPROM in either of the two cases described

Strany 28

34 6.12 Example of LRC calculations Following is an example of calculating LRC with VisualBasic6.0. Variables are declared as shown below. Vis

Strany 29

35 7. Specifications 7.1 Communications standard category Compliant with EIA standard RS-485 7.2 Communications specifications 7.2.1 Commun

Strany 30

36 8. Connections Host Computer (Master Station)Unit1(Slave Station)Unit2(Slave Station)Unit3(Slave Station)A(+)B(-)A(+)B(-)A(+)B(-)A(+)B(-)termina

Strany 31

37 9. Table of identifiers (codes) For the setting range, options, initial values, and similar parameters, see the operation manual for this syst

Strany 32

38 Identifier Relative address Absolute address Character Name R/W Description □MD 0028h 40041 Control mode setting R/W R/W the control mode set

Strany 33

39 Identifier Relative address Absolute address Character Name R/W Description E1B 0068h 40105 Abnormal for EV1 R/W R/W the special event output 1

Strany 34

4 1. Before using the product 1.1 On this operation manual This is an operation manual regarding communications with a TTM-000 Series (hereinafter

Strany 35 - 7. Specifications

40 Identifier Relative address Absolute address Character Name R/W Description TRP 00A2h 40163 Transfer output normal/reverse switch setting R/W R

Strany 36 - 8. Connections

41 10. Table of ASCII codes Upper Lower 00h 10h 20h 30h 40h 50h 60h 70h 00h NUL DEL SPACE 0 @ P ` p 01h SOH DC1 ! 1 A Q a q 02h STX

Strany 37

42 TOHO ELECTRONICS INC. Head office: 1-13-21, Tanashioda, Chuo-ku, Sagamihara-shi, Kanagawa 252-

Strany 38

5 2. Settings regarding TOHO communications 2.1 Overview Before communications is performed, initial settings must be made on this product. Ente

Strany 39

6 2.2 Setting a data length 2.3 Setting a stop bit length 2.4 Setting a parity 2.5 Setting whether to conduct a BCC check While in the &qu

Strany 40

7 2.8 Setting a response delay Set a time from the time when the high-level computer finished sending a "request message" until the time

Strany 41 - 10. Table of ASCII codes

8 3. TOHO communications control 3.1 Communications procedure This product returns a "response message" in response to a "request

Strany 42

9 3.3 Composition of a request message (transmitted from a high-level computer to this product) For codes ① to ⑩, see "3.5 Description

Komentáře k této Příručce

Žádné komentáře